Model 40.10 special features:
|
![]() |
- automatic-dry-point-detection-system for solvents, including thermocouple, 200 ml flask, PTFE plug, and accessories.
- Emergency ”STOP ALL” switch.
- New, slim design.
- Learning Program.
- Built-in, Windows-based PC, with 10,4“ TFT active color LCD-Display with Touch-Screen for a most comfortable operation of the analyzer, including:
– Intel Atom microprocessor.
– 16 GB compact flash card.
– Ethernet interface for intranet connection.
– USB plugs for possible connections of:
– Keyboard.
– Mouse / trackball.
– Printer.
– Software package.
– Windows software.
NEW Automatic Distillation Apparatus Model 40.10
![]() |
![]() |
![]() |
![]() |
with installed microprocessor control and integrated MS-Windows 7 PC used for distillation products, solvents, and crude oil in accordance the following standards:
ASTM D86 (group 0-4), ASTM D216, ASTM D285 (modified), ASTM D447, ASTM D1078 (internal standardized with solvents and group 7 and 8), IP 123, ISO 3405 and DIN 51751.
Multiple units may be linked to a central PC.
The units are programmed with all necessary distillation parameters. All units can operate independently.
All relevant distillation data is stored on the built-in PC and can optionally be stored on a network device, e.g. a server, NAS or dedicated storage device or USB devices.
Example of different distillations:
ASTM D86 | group 0,1,2,3: Distillation of hydrocarbon up to 300°C FBP, e.g. all type of petrol, aviation, turbine fuel etc. |
ASTM D86 | group 4: Distillation of diesel fuel, gas oil, furnace oil, heavy product etc, up to 450°C FBP. |
ASTM D1078 | group solvents. (visual - manual dry point-detection). |
ASTM D1078 | group solvents (automatic dry point detection). |
ASTM D1078 | group 7 and 8 (modified dry point detection). |
ASTM D285 | (modified), group 6: Distillation of crude oil |
Main voltage: | 110 ~ 235 V AC, 50 ~ 60 Hz, ± 10% (wide range input). |
Operation voltage: | 24 V DC. |
Connecting cable: | approx. 2 m long. |
Required power input: | approx. 2,0 kW. |
Recommended main fuse: | 16 A lag. |
Dimensions approx.: | width 515 mm, depth 500 mm, height 670 mm. |
Weight: | approx. 56,0 kg. |
Ambient Temperature: | 16°C ~ 32°C (60°F ~ 90°F). |
Humidity: | 10 % – 65%. |
Each of our analyzers will be delivered with the following standard accessories
for immediately operation:
– Distillation flask 125 ml
– Distillation flask 200 ml
– Ceran plate with hole 32 mm [1]
– Ceran plate with hole 37,5 mm [1]
– Ceran plate with hole 50 mm [1]
– Resistance thermometer Pt 100 with cable and plug.
– Special graduated receiver cylinder complete with metal base.
– Wiper for condenser tube.
– Instruction manual printed in English.